| ZRF-PID-1201 | P&ID - Condensate Export Pumps and Discharge | Read |
| ZRF-REG-LL-001 | Piping Line List | Read |
| ZRF-SPC-3300 | Piping Material and Pressure Testing Specification | Read |
| ZRF-CTR-APX-A | Contract Appendix A - Scope of Work | Read |
| Reference | What it requires |
|---|---|
| REQ-A-014 | The hydrostatic test pressure shall be not less than 1.5 times the design pressure of the line under test. |
| REQ-S-3300-18 | The test medium shall be filtered potable water with a chloride content of not more than 30 ppm. |
| REQ-S-3300-22 | The test pressure shall be held for not less than 2 hours with no visible leakage and no pressure loss. |
| REQ-D-011 | Pressure testing shall be witnessed by the Company representative and the record signed before reinstatement. |
| REQ-ISO-15649-9 | Pressure testing requirements for piping systems. Clause text not reproduced: no licensed copy is held. |
What a grounded answer would have to do
- Cite one of the records above for every statement it makes.
- Refuse to state a value that two documents disagree about, rather than picking the more confident reading.
- Say that a figure is unverified where it is, rather than presenting a reading as a fact.
- Decline the question entirely where the grounding set holds nothing relevant, instead of generalising.