Document classification
What EDS thinks each document is, how sure it is, and what a person has confirmed.
Why
The proposed class and its confidence are the classifier's own. A document that was never read has no classification rather than a low-confidence one.
Writes are validated against the engineering rules and then refused, because no database has been configured for this environment.
Documents
25
Classified with confidence
13
Below 85%
11
Never classified
1
| Document | Title | Proposed class | Confidence | |
|---|---|---|---|---|
| ZRF-PID-1201 | P&ID - Condensate Export Pumps and Discharge | pid | 90%Unverified | Read as this class |
| ZRF-PID-1202 | P&ID - Condensate Export Metering | pid | 90%Unverified | Read as this class |
| ZRF-PID-1101 | P&ID - Inlet Separation (scanned) | pid | 90%Unverified | Read as this class |
| ZRF-PID-3101 | P&ID - Cooling Water Circulation (mixed) | pid | 90%Unverified | Read as this class |
| ZRF-PID-3201 | P&ID - Instrument Air and Nitrogen | pid | 90%Unverified | Read as this class |
| ZRF-PFD-1200 | PFD - Condensate Export | pfd | 90%Unverified | Read as this class |
| ZRF-PFD-1100 | PFD - Inlet Reception | pfd | 90%Unverified | Read as this class |
| ZRF-SLD-6001 | Single Line Diagram - Utilities MCC | single_line_diagram | 90%Unverified | Read as this class |
| ZRF-DS-P-1201A | Equipment Datasheet - Condensate Export Pump P-1201A | datasheet | 75%Unverified | Read as this class |
| ZRF-DS-PT-1201 | Instrument Datasheet - Pressure Transmitter PT-1201 | datasheet | 75%Unverified | Read as this class |
| ZRF-DS-PSV-1210 | Relief Device Datasheet - PSV-1210 | datasheet | 75%Unverified | Read as this class |
| ZRF-REG-EQ-001 | Equipment Register | equipment_list | 95%Unverified | Read as this class |
| ZRF-REG-LL-001 | Piping Line List | line_list | 95%Unverified | Read as this class |
| ZRF-REG-II-001 | Instrument Index | instrument_index | 95%Unverified | Read as this class |
| ZRF-REG-VR-001 | Valve Register | valve_register | 95%Unverified | Read as this class |
| ZRF-REG-CS-001 | Cable Schedule | cable_schedule | 95%Unverified | Read as this class |
| ZRF-REG-MDR-001 | Master Document Register | schedule | 75%Unverified | Read as this class |
| ZRF-SPC-3300 | Piping Material and Pressure Testing Specification | specification | 75%Unverified | Read as this class |
| ZRF-SPC-4100 | Instrumentation and Control Specification | specification | 75%Unverified | Read as this class |
| ZRF-CTR-APX-A | Contract Appendix A - Scope of Work | contract_appendix | 75%Unverified | Read as this class |
| ZRF-CTR-APX-D | Contract Appendix D - Quality and Inspection Requirements | contract_appendix | 75%Unverified | Read as this class |
| ZRF-CTR-APX-F | Contract Appendix F - Documentation and Deliverables | contract_appendix | 75%Unverified | Not read yet |
| ZRF-VND-P-1201 | Vendor Manual - Condensate Export Pump | vendor_manual | 75%Unverified | Not read yet |
| ZRF-SCH-0001 | Project Schedule - Detailed Design and Construction | schedule | 75%Unverified | Read as this class |
| ZRF-PID-9001 | P&ID - Flare Header (unreadable scan) | pid | never classified | Unreadable |
The class decides how a document is read
Confirm or correct a class
Never classified is not low confidence
A document whose processing was refused has no classification at all: nothing read it, so nothing formed an opinion. Showing that as a low-confidence guess would invite somebody to confirm a class nobody proposed.