Menu

Document classification

What EDS thinks each document is, how sure it is, and what a person has confirmed.

Demonstration project - no figure here describes a real facilityChanges are not saved
Why

The proposed class and its confidence are the classifier's own. A document that was never read has no classification rather than a low-confidence one.

Writes are validated against the engineering rules and then refused, because no database has been configured for this environment.

Documents

25

Classified with confidence

13

Below 85%

11

Never classified

1

Document classification (25)
DocumentTitleProposed classConfidence
ZRF-PID-1201P&ID - Condensate Export Pumps and Dischargepid90%UnverifiedRead as this class
ZRF-PID-1202P&ID - Condensate Export Meteringpid90%UnverifiedRead as this class
ZRF-PID-1101P&ID - Inlet Separation (scanned)pid90%UnverifiedRead as this class
ZRF-PID-3101P&ID - Cooling Water Circulation (mixed)pid90%UnverifiedRead as this class
ZRF-PID-3201P&ID - Instrument Air and Nitrogenpid90%UnverifiedRead as this class
ZRF-PFD-1200PFD - Condensate Exportpfd90%UnverifiedRead as this class
ZRF-PFD-1100PFD - Inlet Receptionpfd90%UnverifiedRead as this class
ZRF-SLD-6001Single Line Diagram - Utilities MCCsingle_line_diagram90%UnverifiedRead as this class
ZRF-DS-P-1201AEquipment Datasheet - Condensate Export Pump P-1201Adatasheet75%UnverifiedRead as this class
ZRF-DS-PT-1201Instrument Datasheet - Pressure Transmitter PT-1201datasheet75%UnverifiedRead as this class
ZRF-DS-PSV-1210Relief Device Datasheet - PSV-1210datasheet75%UnverifiedRead as this class
ZRF-REG-EQ-001Equipment Registerequipment_list95%UnverifiedRead as this class
ZRF-REG-LL-001Piping Line Listline_list95%UnverifiedRead as this class
ZRF-REG-II-001Instrument Indexinstrument_index95%UnverifiedRead as this class
ZRF-REG-VR-001Valve Registervalve_register95%UnverifiedRead as this class
ZRF-REG-CS-001Cable Schedulecable_schedule95%UnverifiedRead as this class
ZRF-REG-MDR-001Master Document Registerschedule75%UnverifiedRead as this class
ZRF-SPC-3300Piping Material and Pressure Testing Specificationspecification75%UnverifiedRead as this class
ZRF-SPC-4100Instrumentation and Control Specificationspecification75%UnverifiedRead as this class
ZRF-CTR-APX-AContract Appendix A - Scope of Workcontract_appendix75%UnverifiedRead as this class
ZRF-CTR-APX-DContract Appendix D - Quality and Inspection Requirementscontract_appendix75%UnverifiedRead as this class
ZRF-CTR-APX-FContract Appendix F - Documentation and Deliverablescontract_appendix75%UnverifiedNot read yet
ZRF-VND-P-1201Vendor Manual - Condensate Export Pumpvendor_manual75%UnverifiedNot read yet
ZRF-SCH-0001Project Schedule - Detailed Design and Constructionschedule75%UnverifiedRead as this class
ZRF-PID-9001P&ID - Flare Header (unreadable scan)pidnever classifiedUnreadable

The class decides how a document is read

A P&ID goes through symbol detection; a register through a structured read. A document classified wrongly is read by the wrong machinery and produces a register full of nothing - which looks like a processing failure and is a classification one.

Confirm or correct a class

Reclassifying a document already read is refused.

Never classified is not low confidence

A document whose processing was refused has no classification at all: nothing read it, so nothing formed an opinion. Showing that as a low-confidence guess would invite somebody to confirm a class nobody proposed.