ZRF-SPC-3300 Piping Material and Pressure Testing Specification

Revision C1, issued 2026-04-10 for design. 48 pages held.

Requirements from ZRF-SPC-3300
ReferenceClauseWhat it requiresClassConfidence
REQ-S-3300-18clause 18.3The test medium shall be filtered potable water with a chloride content of not more than 30 ppm.mandatory94%UnverifiedAccepted
REQ-S-3300-22clause 22.1The test pressure shall be held for not less than 2 hours with no visible leakage and no pressure loss.mandatory93%UnverifiedAccepted
REQ-SUG-001clause 18Consider recording ambient temperature at the start and end of the hold period, to explain a pressure change that is thermal rather than a leak.informative50%UnverifiedNot accepted

3 requirements extracted from 48 pages. Why

ZRF-SPC-4100 Instrumentation and Control Specification

Revision B, issued 2026-04-18 for design. 36 pages held.

Requirements from ZRF-SPC-4100
ReferenceClauseWhat it requiresClassConfidence
REQ-S-4100-07clause 7.2Every instrument loop shall be checked from the field element to the control system indication before commissioning.mandatory91%UnverifiedAccepted

1 requirement extracted from 36 pages. Why