12-CD-1201-150-A1A Condensate export pump A discharge
line in U-12, subsystem SYS-12-01.
Not verified
Demonstration project - no figure here describes a real facilityChanges are not saved
Why
Each attribute carries the reading behind it. An attribute two documents dispute shows both rather than the more confident one.
Writes are validated against the engineering rules and then refused, because no database has been configured for this environment.
This record is in conflict
- The pump datasheet rates P-1201A at 24 barg and the line list rates its discharge line 12-CD-1201-150-A1A at 26 barg. Both cannot be the design intent for one connected system, and which is right decides the hydrotest pressure.
Nothing here may be cited as a value, and the record cannot be verified until a person decides which document governs.
Attributes
| Attribute | Value | |
|---|---|---|
| size | DN 150 | Unverified |
| piping class | A1A | Unverified |
| design pressure | 26 barg (disputed) | In dispute |
| design temperature | 120 degC | Unverified |
| insulation | None | Unverified |
| test pressure | 39 barg | Unverified |
Evidence
Every reading of this tag, with the parser and confidence behind it.
| Parser | As read | Confidence |
|---|---|---|
| pdf-native | 12-CD-1201-150-A1A | 50%Unverified |
| pdf-native | 12-CD-1201-150-A1A | 50%Unverified |
| xlsx-reader | 12-CD-1201-150-A1A | 50%Unverified |
Documents
| Document | Title |
|---|---|
| ZRF-PID-1201 | P&ID - Condensate Export Pumps and Discharge |
| ZRF-REG-LL-001 | Piping Line List |
Placement
- Tag
- 12-CD-1201-150-A1A
- Class
- line
- Discipline
- PIP
- Unit
- U-12
- Subsystem
- SYS-12-01
- Test pack
- ZRF-TP-001
- Drawn on
- ZRF-PID-1201
What this record rests on
- Confidence
- 50%Unverified
- Readings
- 3
- Verified
- Not yet
The weakest link in the chain, not an average. Why
What stops this being used
- attribute conflict: a safety-critical attribute conflict that presents no value and blocks approval
- nothing machine-read is verified until a person has checked it