Every source document the project holds, with its current revision, how EDS read it, and how many tags it carries.
Why
Rows, counts, filters and sorting are computed from the project's document records and the files themselves.
Writes are validated against the engineering rules and then refused, because no database has been configured for this environment.
Documents
25
Drawings
9
Registers
5
Read by EDS
22
Refused or not read
2
1 refused
| Numberdescending | Title | Class | Rev | Read | |
|---|---|---|---|---|---|
| ZRF-SPC-4100 | Instrumentation and Control Specification | Specification | B | Read | Open |
| ZRF-SPC-3300 | Piping Material and Pressure Testing Specification | Specification | C1 | Read | Open |
| ZRF-SLD-6001 | Single Line Diagram - Utilities MCC | Single line diagram | A | Read | Open |
| ZRF-SCH-0001 | Project Schedule - Detailed Design and Construction | Schedule | C4 | Read | Open |
| ZRF-REG-VR-001 | Valve Register | Valve register | C1 | Read | Open |
| ZRF-REG-MDR-001 | Master Document Register | Schedule | C3 | Read | Open |
| ZRF-REG-LL-001 | Piping Line List | Line list | C2 | Read | Open |
| ZRF-REG-II-001 | Instrument Index | Instrument index | C1 | Read | Open |
| ZRF-REG-EQ-001 | Equipment Register | Equipment list | C1 | Read | Open |
| ZRF-REG-CS-001 | Cable Schedule | Cable schedule | B | Read | Open |
| ZRF-PID-3201 | P&ID - Instrument Air and Nitrogen | P&ID | A | Read | Open |
| ZRF-PID-3101 | P&ID - Cooling Water Circulation (mixed) | P&ID | A | Read | Open |
| ZRF-PID-1202 | P&ID - Condensate Export Metering | P&ID | B | Read | Open |
| ZRF-PID-1201 | P&ID - Condensate Export Pumps and Discharge | P&ID | C3 | Read | Open |
| ZRF-PID-1101 | P&ID - Inlet Separation (scanned) | P&ID | B | Read | Open |
| ZRF-PFD-1200 | PFD - Condensate Export | PFD | B | Read | Open |
| ZRF-PFD-1100 | PFD - Inlet Reception | PFD | A | Read | Open |
| ZRF-DS-PT-1201 | Instrument Datasheet - Pressure Transmitter PT-1201 | Datasheet | A | Read | Open |
| ZRF-DS-PSV-1210 | Relief Device Datasheet - PSV-1210 | Datasheet | A | Read | Open |
| ZRF-DS-P-1201A | Equipment Datasheet - Condensate Export Pump P-1201A | Datasheet | B | Read | Open |
| ZRF-CTR-APX-D | Contract Appendix D - Quality and Inspection Requirements | Contract appendix | 0 | Read | Open |
| ZRF-CTR-APX-A | Contract Appendix A - Scope of Work | Contract appendix | 0 | Read | Open |
Showing 1 to 22 of 22 documents
References the project cannot follow
ZRF-PID-1299 is named by a document the project holds and is not in the library. A continuation that leads nowhere is a gap in the drawing set, not a defect in the drawing that names it.
Refused is not the same as unread
A document EDS refused is one it measured as unreadable and declined to guess at. A document not read is one nothing has been attempted on. Both show zero tags, and treating them the same hides the only one of the two that needs a new file.
What a revision means here
The revision shown is the current one. Earlier revisions are kept and are reachable from each document, because an engineer who cites a drawing cites a revision of it, and a library that only holds the latest cannot tell them what has changed underneath.