Menu

P&ID intelligence

What EDS recognised on one drawing, what it refused to decide, and why.

Demonstration project - no figure here describes a real facilityChanges are not saved
Why

Recognition figures are from the project's own drawings, which EDS generated. They are regression evidence, not an accuracy claim about any real drawing.

Writes are validated against the engineering rules and then refused, because no database has been configured for this environment.

Tags on this sheet

16

Equipment

5

Valves

4

Instruments

4

Findings on it

0

Three things EDS will not decide for you

A crossing is not a connection: two lines meeting on a sheet are usually not joined. A tie is a refusal: where two symbol candidates score equally, nothing is chosen. And a drawn boundary is never an approved system boundary - a dashed box is a drafter’s annotation, and promoting one is how a test pack comes to contain the wrong valves.

What is on the sheet

Each item with the reading behind it.

Items on ZRF-PID-1201
TagDescriptionClassReading
P-1201ACondensate export pump Aequipment50%UnverifiedUnverified
P-1201BCondensate export pump B (spare)equipment80%UnverifiedUnverified
V-1210Condensate surge drumequipment80%UnverifiedVerified
F-1205Condensate export strainerequipment80%UnverifiedUnverified
HV-1201Condensate export discharge isolationvalve80%UnverifiedUnverified
LCV-1210Surge drum level control valvevalve80%UnverifiedUnverified
PSV-1210Surge drum relief valvevalve80%UnverifiedUnverified
CV-1201Condensate export pump A non-returnvalve80%UnverifiedUnverified
PT-1201Condensate export discharge pressureinstrument50%UnverifiedUnverified
LT-1210Surge drum levelinstrument80%UnverifiedUnverified
LIC-1210Surge drum level controllerinstrument80%UnverifiedUnverified
PSH-1201Condensate export high pressure switchinstrument80%UnverifiedUnverified
12-CD-1201-150-A1ACondensate export pump A dischargeline50%UnverifiedUnverified
12-CD-1202-150-A1ACondensate export headerline80%UnverifiedUnverified
12-CD-1203-100-A1ASurge drum level control lineline80%UnverifiedUnverified
M-1201ACondensate export pump A motorequipment80%UnverifiedUnverified

This drawing

Number
ZRF-PID-1201
Class
pid
Format
pdf_vector
Read by
native_text
Continuations
ZRF-PID-1202, ZRF-SPC-3300

Symbol taxonomy

What the recogniser knows how to look for, across disciplines.

  • piping6 symbols
  • process4 symbols
  • instrumentation4 symbols
  • mechanical2 symbols
  • safety2 symbols

Raster recognition is capped at 60%. Why

The legend is evidence, not decoration

Where a drawing carries its own legend, the legend corroborates a symbol reading and raises its confidence - to a ceiling, never to certainty. A customer whose legend draws a globe valve the way everybody else draws a gate valve is not wrong; their drawing says what their legend says.