Menu

Extraction verification

Everything read from a document and not yet checked by a person, ordered by consequence rather than by confidence.

Demonstration project - no figure here describes a real facilityChanges are not saved
Why

The queue is computed from the project's traceability records. A record in conflict is listed and cannot be verified.

Writes are validated against the engineering rules and then refused, because no database has been configured for this environment.

Awaiting verification

49

Safety critical

4

In conflict

4

Ready to check

45

Nothing selected of 49

Verification queue (49), by consequence
TagDescriptionConfidence
PSV-1110
Inlet separator relief valve
60%UnverifiedSafety critical
PSH-1201
Condensate export high pressure switch
80%UnverifiedSafety critical
PSV-1210
Surge drum relief valve
80%UnverifiedSafety critical
XV-1205
Condensate export shutdown valve
80%UnverifiedSafety critical
P-1201A
Condensate export pump A
50%Unverified
In conflictattribute conflict: a safety-critical attribute conflict that presents no value and blocks approval
PT-1201
Condensate export discharge pressure
50%Unverified
In conflictnear duplicate tag: a near-duplicate finding that blocks use of both readings
HV-3101
Cooling water pump A isolation
50%Unverified
In conflictboundary disagreement: a placement conflict in which nothing is chosen and the drawn boundary is never promoted
12-CD-1201-150-A1A
Condensate export pump A discharge
50%Unverified
In conflictattribute conflict: a safety-critical attribute conflict that presents no value and blocks approval
E-1217
Condensate export cooler B (register only, drawn on no sheet)
50%UnverifiedUnverified
V-1110
Inlet separator
60%UnverifiedUnverified
K-1120
Inlet booster compressor
60%UnverifiedUnverified
PT-1101
Inlet separator pressure
60%UnverifiedUnverified
LT-1110
Inlet separator level
60%UnverifiedUnverified
AT-1105
Inlet gas H2S analyser
60%UnverifiedUnverified
11-NG-1101-300-B2B
Inlet gas to separator
60%UnverifiedUnverified
P-3101A
Cooling water pump A
70%UnverifiedUnverified
P-3101B
Cooling water pump B
70%UnverifiedUnverified
T-3110
Cooling water buffer tank
70%UnverifiedUnverified
PT-3101
Cooling water header pressure
70%UnverifiedUnverified
TT-3102
Cooling water supply temperature
70%UnverifiedUnverified
31-CW-3101-400-C1C
Cooling water supply header
70%UnverifiedUnverified
31-CW-3102-400-C1C
Cooling water return header
70%UnverifiedUnverified
P-1201B
Condensate export pump B (spare)
80%UnverifiedUnverified
E-1216
Condensate export cooler
80%UnverifiedUnverified
F-1205
Condensate export strainer
80%UnverifiedUnverified
K-3201
Instrument air compressor
80%UnverifiedUnverified
V-3210
Instrument air receiver
80%UnverifiedUnverified
PT-1202
Condensate export header pressure
80%UnverifiedUnverified
TT-1203
Condensate export temperature
80%UnverifiedUnverified
LT-1210
Surge drum level
80%UnverifiedUnverified
LIC-1210
Surge drum level controller
80%UnverifiedUnverified
FT-1204
Condensate export flow
80%UnverifiedUnverified
PT-3201
Instrument air header pressure
80%UnverifiedUnverified
HV-1201
Condensate export discharge isolation
80%UnverifiedUnverified
HV-1202
Condensate export header isolation
80%UnverifiedUnverified
LCV-1210
Surge drum level control valve
80%UnverifiedUnverified
CV-1201
Condensate export pump A non-return
80%UnverifiedUnverified
HV-3201
Instrument air header isolation
80%UnverifiedUnverified
12-CD-1202-150-A1A
Condensate export header
80%UnverifiedUnverified
12-CD-1203-100-A1A
Surge drum level control line
80%UnverifiedUnverified
12-CW-1210-100-C1C
Cooling water supply to condensate export cooler
80%UnverifiedUnverified
32-IA-3201-80-C1C
Instrument air header
80%UnverifiedUnverified
M-1201A
Condensate export pump A motor
80%UnverifiedUnverified
M-1201B
Condensate export pump B motor
80%UnverifiedUnverified
MCC-6001
Utilities motor control centre
80%UnverifiedUnverified
TX-6010
Utilities distribution transformer
80%UnverifiedUnverified
C-60101
MCC-6001 to M-1201A power cable
80%UnverifiedUnverified
C-60102
MCC-6001 to M-1201B power cable
80%UnverifiedUnverified
C-60201
Instrument multicore to JB-1201
80%UnverifiedUnverified

Showing 1 to 49 of 49 records

Page 1 of 1

Ordered by consequence, not by confidence

A queue ordered by confidence puts a cable tray read at 0.4 above a relief valve read at 0.9, and whoever works through it spends the morning on the cable tray. Safety-critical first, then anything in conflict, then the least confident.

Verify one

Recorded against you by name. A disputed value cannot be verified.

Rows in conflict are not offered

Leave blank to verify the record rather than one value

Why a conflict cannot be verified

There is nothing to verify until one document governs. Why