Which contract and standard requirements this deliverable must satisfy, proposed and unconfirmed.

Demonstration project - no figure here describes a real facilityChanges are not saved
Why

Proposals are matched from the project's own requirement set. Applicability is a judgement and every proposal is marked unconfirmed.

Writes are validated against the engineering rules and then refused, because no database has been configured for this environment.

  1. Type and scope
  2. 2Requirements
  3. 3Inputs
  4. 4Template
  5. 5Structure

Requirements on the project

9

Proposed for this type

7

Confirmed

0

In conflict with each other

2

Applicability is a judgement, not a lookup

A requirement mentioning hydrostatic testing applies to a hydrotest procedure. Whether one about welding qualification applies depends on whether this procedure covers reinstatement, and only a person knows that. Every proposal below is unconfirmed.

Two proposed requirements contradict each other

REQ-D-011, REQ-S-3300-22 are in an unresolved conflict. Attaching both would give the deliverable two incompatible obligations, and neither is applicable until somebody records which governs.

Proposed for Hydrotest procedure

With the reason each one was proposed.

Proposed requirements
ReferenceWhat it requiresSourceWhy proposed
REQ-A-014
The hydrostatic test pressure shall be not less than 1.5 times the design pressure of the line under test.
ZRF-CTR-APX-A
the requirement names this deliverable type
UnconfirmedDecide
REQ-A-021
The Contractor shall submit every deliverable listed in the master document register for Company review before construction.
ZRF-CTR-APX-A
the requirement names this deliverable type
UnconfirmedDecide
REQ-D-011
Pressure testing shall be witnessed by the Company representative and the record signed before reinstatement.
ZRF-CTR-APX-D
the requirement names this deliverable type
UnconfirmedDecide
REQ-S-3300-18
The test medium shall be filtered potable water with a chloride content of not more than 30 ppm.
ZRF-SPC-3300
the requirement names this deliverable type
UnconfirmedDecide
REQ-S-3300-22
The test pressure shall be held for not less than 2 hours with no visible leakage and no pressure loss.
ZRF-SPC-3300
the requirement names this deliverable type
UnconfirmedDecide
REQ-ISO-15649-9
Pressure testing requirements for piping systems. Clause text not reproduced: no licensed copy is held.
ISO 15649
the requirement names this deliverable type
UnconfirmedDecide
REQ-SUG-001
Consider recording ambient temperature at the start and end of the hold period, to explain a pressure change that is thermal rather than a leak.
ZRF-SPC-3300
the requirement names this deliverable type
UnconfirmedDecide

Contract obligations to consider

An unconfirmed obligation cannot become a requirement.

Contract obligations
ReferenceAppendixObligation
OBL-A-001AThe Contractor shall provide engineering services for the detailed design of the condensate export and utilities systems.Confirmed
OBL-A-002AThe Contractor shall submit for approval the deliverables listed in the master document register.Confirmed
OBL-D-001DAn inspection and test plan shall be submitted, identifying every witness point and hold point.Confirmed
OBL-D-002DThe quality plan shall define the inspection and test plan for the works.Reads two ways
OBL-F-001FDeliverables shall be issued in accordance with the Company numbering convention and the deliverable schedule.Reads two ways

Does REQ-D-011 apply?

A proposal matched on a word is a shortlist. Accepting one needs the reason it rests on.

Pressure testing shall be witnessed by the Company representative and the record signed before reinstatement.

Excluding a contract requirement is the decision nobody questions until the hold point

Pick a type

Why nothing is attached automatically

A wizard that silently attached a requirement set would produce a deliverable claiming to satisfy requirements nobody checked were relevant - and the claim would appear in the traceability matrix as compliance.

A source the project does not hold

  • REQ-ISO-15649-9ISO 15649 not held